Improves working conditions and increases productivity with new technolgy without power or operating costs.

Natural economical effective ventilation all year round without power or operation costs. Improves working conditions and increases productivity. An energy saver for a better tomorrow.

How does it work

The turbine ventilator operates by utilising the velocity energy of the wind to induce air flow by centrifugal action. The centrifugal force caused by the spinning vanes creates a region of low pressure are which draws air out throughthe turbine. The slightest breeze will cause the trubine to sin and even after the breeze has stopped, the fly wheel effect of the rotor cage will use its stored energy to continuously remove air giving rise to ventilation. Suction is maintained even at low wind velocities..

Features

  • Rigid roll formed curved vanes.
  • Weatherproof and stormproof
  • Light weight and durable
  • Natural light from shade
  • Noise free
  • Virtually maintenance free
  • Zero running cost
  •  Warranty: 5 yrs

The benefit of natural ventilation system:

Factories, warehouses, workshops and even community building are frequently constructed without an efficient natural ventilation system for the benefit of occupants. And, if the interior of the building gets hot and stale, there's always door of windows that can be opened to provide for the ventilation. However, stale and hot air doesn't disperse by itself and opening doors or windows is simply not sufficient to provide adequate ventilation in most buildings. But, by installing Turbovent trubine ventilators, you can provide an efficient and cost effective system of nature ventilation for the benefit of the building's occupants. These wind driven ventilators, unlke doors or window, draw air upwards, creating a convection current, and in the process they extract stale air, together with air which ha become hot due to the building's exposure to long hours of sunlight and from naufacturing processes within the building. As the stale and hot air is extracted by the ventilaotrs, it is replaced by fresh air at ambient temperature entering through doorways and opening thus completing the convection cycle current and improving the internal environment. Needless to say, fresh air make people feel more energetic whilst stale air causes people to feel tired and on hot days the air movement over the body causes evaporation to occur which is the natual way of cooling down and reducing heat stress on the body. Airvent Turbine ventilator also help to prevent condensation by extracting moist condensate forming air,and in the case of fire will extract smoke and fumes thus preventing the building from becoming smoke filled and allowing the occupants to escape to safety.

Technical Specification


Model

RTV 24

Dome size

28(inch)

Hight

18(inch)

Throat Size(in)

21(inch)

MOC blades

Alluminium

Blade guage

24 SWG

No of Blades

36

Top Dish

S.S.

Top dish guage

22 SWG

Bottom Ring

S.S.

Bottom Ring Guage

22 SWG

Riveting

POP

FRP base thickness

2 mm

FRP Hight

24(inch)

FRP Size

72x39(inch)

Weight of Fan

7 kg

Weight of RP Base

7 kg

Revit Bush

Teflon Graphite Bush

Sahft

Mield Steel

Recommended Air Change Rate


Type of Building

Air Changes p/hr.

Assembly Hall

06 to 12

Auditorium

04 to 12

Bakeries

12 to 20

Boiler Room

15 to 60

Brewery

08 to 30

Class Room

10 to 15

Engine Room

12 to 30

Factories (Light)

06 to 12

Factories (Heavy)

10 to 30

Laundry

12 to 30

Paper Mill

08 to 30

Textile Mill

04 to 12

Packing Room

08 to 30

Transformer Room

12 to 30

Paint Shop

10 to 30

Warehouse

04 to 06


Technical Specification
Wind velocity (MPH) 5 8 10
Temp Diff. ¡C 3 5 10 3 5 10 3 5 10
Model No Stack (Height Ft.) Exhaust
RTV 24 10
1163 1252 1400 1763 1852 2000 2187 2276 2424

20
1257 1372 1564 1857 1972 2164 2282 2396 2586

30
1339 1476 1704 1939 2076 2304 2363 2500 2728

40
1407 1564 1826 2007 2164 2426 2428 2586 2850

All Technical Specification & data can be changed for any modification.
<< Back


CONTACT DETAILS
B-512, 2nd Floor, Nehru Ground, N.I.T.,Faridabad - 121001, Haryana, India
Phone:91-129-2431386/4033386/4127458
Fax:91-129-4033386/2431386
Send Mail     
Key Personnel
Mr. R. G. Gupta
Mobile:+919811086720
Mr. Ashish Gupta
Mobile:+919810653051
Mr. Arvind R Gupta
Mobile:+919323788100

 
 
Copyright © 2009 by NANOTEK INDUSTRIAL CONTROLS & ENGINEERS All Rights Reserved.